GALVANIZED STEEL CORE WIRE FOR ALUMINIUM CONDUCTOR
Nominal
diameter, |
Tolerance |
UltimateTensile
strength , |
Elongation, |
Stress at
1%-extension, |
|
1,85 |
2,4 |
0,1;-0,03 |
1340 |
4 |
1190 |
2,45 |
2,65 |
1300 |
1160 |
||
2,7 |
2,95 |
0,12;-0,03 |
|||
3,05 |
3,4 |
1120 |
|||
3,6 |
4,5 |
1200 |
|||
Wire Diameter, |
Group I |
Group II |
||
Zinc coating |
Number of dips |
Zinc coating, |
Number of dips |
|
1,85 - 2,00 |
70 |
2 |
90 |
3 |
2,20 - 2,40 |
80 |
2 |
100 |
4 |
2,65 - 3,05 |
100 |
3 |
120 |
|
3,20 - 4,50 |
150 |
5 |
||
![]()
GENERAL PURPOSE GALVANIZED STEEL WIRE STRAND
Code name |
Total area |
Stranding and wire
diameter |
Overall diameter |
Ultim. Ìass, |
Breaking Strenth |
||
300 MPa |
700 MPa |
1370 MPa |
|||||
C25 |
24,25 |
7x2,1 |
6,3 |
0,17 |
6,55 |
15,35 |
30,11 |
C35 |
34,36 |
7x2,5 |
7,5 |
0,27 |
11,57 |
24,08 |
30,11 |
C50 |
49,48 |
7x3,0 |
9 |
0,39 |
14,8 |
34,62 |
67,65 |
48,35 |
19x1,8 |
9 |
0,38 |
14,5 |
33,8 |
66,21 |
|
C70 |
65,81 |
19x2,1 |
10,5 |
0,47 |
17,9 |
41,75 |
81,73 |
C95 |
93,27 |
19x2,5 |
12,5 |
0,74 |
22,97 |
127,7 |
|
C120 |
134,2 |
19x3,0 |
15 |
1,06 |
40,27 |
188 |
|
This specification covers three grades of tensile steel wires-Grade 300 and 700-from galvanized low carbon steel wires and Grade 1370-from galvanized steel core wire for aluminium conductors, steel reinforced